ICM ICM292A Furnace Control Boards, Rheem Replacement Boards

Availability:
In-Stock

Direct Spark Ignition (DSI) Control Board

The ICM292A is a low-cost DSI gas ignition control that replaces the following Rheem model: 62-24140-04. The ICM292A has incorporated LED diagnostics to assist in troubleshooting.

Fault code information can be found in the application guide. Please refer application guide with the furnace installation manual for future reference.

DETAILS:

  • Low cost form, fit and functional replacement for Rheem: 62-24140-04
  • Direct Spark Ignition (DSI) control
  • Microprocessor-based
  • Controls induced draft and indoor blower motor; humidifier output, spark ignitor and gas valve
  • Monitors timing, trial for ignition, flame sensing and lockout
    100% lockout safety feature
  • Compatible with LP or natural gas
  • Status LEDs for fault codes to aid in troubleshooting 

$171.00 USD

Title
Buy Now
SKU:
ICM292A
ID:
PH501-2S9-3257

SPECIFICATIONS


General Information 

Control  Voltage:
24 VAC (18-30 VAC), 60 Hz
Line Voltage:
115 VAC, 60 Hz
Power cons:  30 seconds 
Trial for ignition:
7 seconds
Retries:
Two groups of two, 30 seconds delay within the group and 3 minutes delay between group
Lockout:
1 hour
Post-purge:90, 120, 160 and 180 seconds
Power: 
24 VAC and COM
Thermostat interface: R, W, Y and G



General Information 

System switches:
Vent pressure and limit switches (main and over-temperature switches in series)
Heat blower OFF delay: 
SW1 toggle switch
Gas Valve: 3A Pilot Duty @ 120 VAC
Draft Inducer Motor:
3A max., 1/6 HP @ 125 VAC
Cool Blower: 14A max., 1/2 HP @ 277 VAC
Heat Blower: 14A max., 1/2 HP @ 277 VAC
Circulating Fan:
12A max., 1 HP @ 125 VAC
Heat/Cool Fan:
10 A max., 1/2 HP @ 277 VAC
Electronic Air Cleaner:
10 A max., 1HP @ 125 VAC
Humidifier:11 A max., 1/6 HP @ 125 VAC