ICM ICM253 Fan Blower Control - Off Delay on Break (12-390 Second Adjustable Delay)

Availability:
In-Stock

Replaces: Field Controls: 461447700; Gemline: 1C216; Mars: 32393

$26.58 USD

Title
Buy Now
SKU:
ICM253B
ID:
PH501-2S9-3208

PRODUCT INFO

Controls the circulating fan in heat pump, air conditioning and forced air systems. Off delay timing function continues to run the fan at the end of the heating/cooling cycle, thereby purging ducts of residual air and increasing system efficiency.

Product Features

  • UL 873 recognition for compressor applications
  • Post-purge fan delay timer
  • OFF delay purges ducts of residual air at the end of the heating/cooling cycle
  • Interrogation delay eliminates nuisance trips due to thermostat bounce/tampering

Mode of Operation - Power must be applied before and during the time delay period. When the initiate contact closes, the load energizes and remains energized as long as the initiate contact is closed. The time delay begins when the initiate contact opens. At the end of the time delay period, the load is turned off. If the initiate contact re-closes during the time delay period, the load remains energized and the time delay is reset to zero. Removal of the input power during the delay turns off the load and resets the time delay to zero. A one-second interrogation delay is provided to avoid nuisance trips due to thermostat bounce or tampering.

SPECIFICATIONS

General Information    

Voltage
18/30 VAC
Amperage
1 (Max)
Amp Inrush
10
Dimensions
2" x 3"
Frequency
50-60 Hz
Holding Current
40 mA (minimum)
Adjustable Time Delay
12-390 Seconds