ICM ICM2904 Intermittent Pilot Ignition Control (Replaces Reznor 257009)
Replaces: Reznor: 257009; UTEC: 1003-638A
$96.82 USD
SKU:
ICM2904
ID:
PH501-2S9-3162
Categories:
PRODUCT INFO
*Intermittent pilot gas ignition control module*For use with intermittent pilot boilers, furnaces and other heating appliances* Microprocessor-based*Remote flame sensing*Compatible with LP or natural gas*Brown out monitoring
Features
- Intermittent Pilot Gas Ignition Control Module
- For use with intermittent pilot boilers, furnaces and other heating appliances
- Microprocessor-based
- Monitors timing, trial for ignition, and flame sensing
- Remote flame sensing
- 100% lockout safety feature
- Compatible with LP or Natural Gas
- Brown out monitoring circuit
Specifications
- Control Voltage: Line 18-30VAC 50/60 Hz
- Pilot Valve: 1A @24VAC
- Main Gas Valve: 2A @24VAC
- Current Draw: 100mA maximum
- Pre-Purge Delay: 0 seconds
- Ambient Operating Temperature: -40ºF to 167ºF -40C to 75°C
- Humidity: 5%-95% R.H. (non-condensing) at +55°C
SPECIFICATIONS
General Information | |
Product Type | Intermittent Pilot Gas Ignition |
Anticipator Setting | 2A plus valve load @ 24 VAC |
Ignition Type | Intermittent Pilot |
Relative Humidity | 5% to 95% R.H. (non condensing) |
OEM | Reznor |
Control Voltage | Line 24V (18-30 VAC) 50-60Hz |
Pre-Purge Time | 0 Seconds |
Operating Temp Range | -40° to 167°F |
Replaces | 257009 |