ICM ICM2909 Furnace Control Boards,Rheem Replacement Boards
Replaces: Rheem: 62-23599-01, 62-23599-02, 62-23599-03, 62-23599-04, 62-23599-05
$158.25 USD
                    SKU:
                    
                  
                      ICM2909
                    
                  
                      ID:
                      
                  
                        PH501-2S9-3251
                      
                    
                    Categories:
                    
                  
                  
                  
                PRODUCT INFO
Direct Spark Ignition (DSI) Control Board
The ICM2909 DSI control replaces the following Rheem models: 62-23599(-01,-02,-03,-04,-05). The ICM2909 has incorporated LED diagnostics to assist in troubleshooting. Fault code information can be found in the application guide.
DETAILS:
- Rheem Replacement (DSI) control board
 - Direct Spark Ignition (DSI) control board
 - Microprocessor-based
 - Monitors timing, trial for ignition, system switches, flame sensing and lockout
 - 100% lockout safety feature
 - Compatible with LP or Natural Gas
 - LED indication for status and fault codes to aid in troubleshooting
 
SPECIFICATIONS
| General Information  | |
| Line voltage: | 208-230 VAC, 50/60 Hz | 
| Control voltage: | 18-30 VAC, 50/60 Hz  | 
| System switches: | Vent pressure, limit and MRLC (Manual Reset Limit Control) | 
| Heat N.C. | 16FLA/30 LRA @ 277 VAC, 30K @ 85°C  | 
| Inducer: | 9.8FLA/58.8LRA, 1/2HP @ 120 VAC, 6K @ 75°C  | 
| Gas valve: | 2.3 A PILOT DUTY @ 240 VAC, 6K @ 75°C  | 
| Operating temperature: | -40˚F to 175˚F (-40˚C to 80˚C) | 
| Storage temperature: | -40˚F to 185˚F (-40˚C to 85˚C) | 
| Humidity: | 5% – 95% R.H. (non-condensing) at +55˚C | 
| Pre-purge: | 3 seconds | ||
| Heat blower ON delay | 30 seconds | ||
| Post-purge: | 5 seconds  | ||
| Heat blower OFF delay: | 90 seconds | ||
| Ignition trial: | 7 seconds | ||
| Inter-purge (retrial): | 15 seconds | ||
| Ignition activation period: | 5 seconds | ||
| Flame establishing period: | 2 seconds | ||
| Flame failure response time: | 0.8 seconds (maximum) | ||
| Cool blower On delay: | 1 second  | ||
| Cool blower Off delay: | 30 seconds  | ||
| Auto reset lockout: | 60 minutes | 

                    