X-404 | Modbus Master Controller
$10,000.00 USD
PRODUCT INFO
Features:
- Connect up to 32 modbus devices/sensors
- 1-Wire Bus for up to 16 sensors (temperature, humidity, etc.)
- Monitor,log, and control up to 32 remote modules, or up to 100 I/O
- User Permissions: Admin, Manager, User
- Tasks
- 50 Scheduled
- 50 Conditional
- 20 Override Schedules
- Send email alerts based on user-defined conditions (supports encrypted email servers, such as Gmail)
- Real-Time Clock with NTP server synchronization
- Automatic daylight savings and leap year adjustment
- No software required
- Customizable web-based Control Page
- BASIC script support for advanced flexibility
- Configurable logging
- Graphing (logged data)
- HTTPS/TLS encrypted
- Static or DHCP IP address configuration
- Modbus, SNMP, Remote Service, IP Filtering
- Field updatable
- Rugged DIN-Rail/wall-mountable enclosure
Modbus Master Controller (Connect up to 32 Modbus Sensors)
1. MODBUS TCP/IP
Up to 32 modbus RS-485 sensors.
2. TASK BUILDER
Easily create custom logic, no scripting neccessary.
3. PEER-2-PEER COMMUNICATION
Share real-time sensor states with other ControlByWeb devices.
4. EMAIL/TEXT ALERTS
Customizable email/text alerts based on sensor states.
5. ON-DEVICE LOGIC
All logic occurs on device, no cloud necessary.
6. WEB-ENABLED
Monitor sensor status using a standard web browser.
7. LOGGING/GRAPHING
Log and graph sensor states over time.
8. INCLUDES 400-SERIES ADVANCED FEATURES
Task Builder, encryption, intuitive user interface, much more.
Industrial Internet of Things (IIoT)
1. Monitoring RS-485 Sensors
The X-404 module functions as a web-based Modbus master controller and monitor for third-party RS-485 modbus sensors and devices. It can monitor up to 32 sensors. Reap the benefits of modbus integration with easy setup, reliability, and daisy-chaining capabilities.
2. Control Options
All ControlByWeb devices, with their various combinations of inputs and outputs, can function as a Modbus/TCP slave device controlled by the X-404 controller.
3. Fluid Level Monitoring
Use the X-404 to monitor fluid levels through the module's Modbus protocol.
4. Remote Monitoring
The X-404 can be connected to and monitor up to 32 different modbus devices. In this illustration, the X-404 is connected to the MPX Float Sensor, as well as the MND Modbus Display for local level monitoring. The X-404 can also be connected to pressure sensors, like the PT-500 for other level monitoring options.
5. Programming
The X-404 module is designed to automatically program modbus sensors when connected, without using an external power supply or separate programming module.
6. Email/Text Alerts
Configure the X-404 to send email/text alerts when the level reaches user-defined high/low paramaters. Enable logging to record the history of sensor states.
Electromagnetic Compliance:
- IEC CISPR 22, CISPR 24
- EU EN55024, EN55022
- X-404-I: FCC 47CFR15 (Class B)
Product Safety Compliance:
- IEC 61010-1
Real-Time Clock:
- Manual or NTP(Network Time Protocol) setup
- NTP Sync Period: Once, Daily, Weekly, On Powerup
- Auto Daylight Savings Adjustment
- Battery (capacitor) Power Backup
SPECIFICATIONS
Power Requirements | |
Voltage | X-404-I (9-28VDC) |
Max Current | No Modbus Sensors: 134mA |
RS-485 Connector | |
Sensors Supported | Up to 32 |
Connector | 5-position, removable terminal strip, 3.81 mm spacing |
Communication | RS-485 |
Temperature Sensors | |
Maximum Number of Sensors | 16 |
Temperature Range | -67°F to 257°F (-55°C to +125°C) |
Accuracy | ±0.5°C (from -10°C to +85°C) |
Sensor Functions | Monitor Temperature, Log Temperature, Email Alerts, SNMP Traps |
Humidity Type | Xytronix Model X-DTHS-P sensor |
Humidity Range | 0-100% RH |
Accuracy | ±2% |
Max Cable Length | 600 feet (180m) maximum combined cable length |
Capacitor Power Backup | |
Backup Functions | Real-time clock, 1 register, 2 counters, 64 relay states (remote modules only) |
Backup Duration | 2 week minimum |
Network | |
Type | 10/100 Base-T Ethernet Port |
Setup | Static or DHCP IP address configuration |
Connectors | |
Modbus Bus | 5-Position, 3.81mm terminal spacing, Removable. For 16-28 AWG wire. |
Network | 8-pin RJ-45 |
Power and 1-Wire Bus | 5-Position, 3.81mm, Removable |
LED Indicators | |
Number of LEDs | 3 (Power on; Network linked; Network activity) |
Physical | |
Size | 1.41in (35.7mm) wide 3.88in (98.5mm) tall 3.1in (78mm) deep (not including connector) |
Operating Temperature | -40°F to 150°F (-40°C to 65.5°C) |
Weight | 0.3 lb |
Enclosure Material | Lexan 940 Polycarbonate Plastic |
Enclosure Flame Rating | UL94 V0 |
Password Settings | |
Password Length | 6-18 Characters |
Protocols | HTTP, HTTPS, SSL, XML, Modbus TCP/IP, SNMP V1,2C,V3, SMTP, Modbus RS-485 |
Logging | |
Log File Size | 3,072-Kbyte (up to 50,688 logs) |
Storage | Nonvolatile Flash |
Buffer Architecture | Circular Buffer |