Stand-alone water leak detector monitors the presence of liquids, sends alarm notifications, and provides real-time sensor status via web browser

$10,000.00 USD

Sold Out

SKU:
XW-112-5+PS5V-2605

PRODUCT INFO

Water leaks can occur when you least expect them! Leaks that are left undetected can lead to thousands of dollars worth of repairs and equipment replacement costs. With the XW-112 you can monitor water leaks in server rooms, around water heaters, bathrooms, and areas near water tanks or pipes. Don't let a leaky pipe set you back!
The XW-112 is an easy-to-use and effective water leak detection system. This wireless device monitors the presence of conductive, non-flammable liquids using a GRI-2605 liquid detection sensor (included). It's ideal for applications where liquid levels or water leaks must be monitored and Ethernet wiring is not accessible or practical to install.

       1. Built-in Web Server
The XW-112 is a self-contained device which does not require any additional equipment such as hubs, gateways, or servers. The XW-112 provides real-time water status to users through a standard web browser or the CBW Mobile app.*

*Note that accessing XW-112 remotely over the Internet requires your local router to be setup to forward incoming requests to the XW-112.

      2. Email/Text Notifications
Receive email/text notifications in the event of a pipe burst, slow leak, or rising water levels.
When the XW-112 Wi-Fi Water Detector detects the presence of water, it sends email notifications to up to 3 email addresses to ensure that the proper personnel is notified. Convert email messages to text messages using your wireless carrier's free email to SMS gateway.

        3. Alarm Control
In addition to email/text notifications, the XW-112 can send messages to control other ControlByWeb devices when it detects the presence of water. For example, a WebRelay that is wired to an alarm notification device, such as a bell or flashing light, can be turned on by the XW-112 when water is detected. These ControlByWeb devices can be located in the same building, across campus, or they can be located in a location that's across the world!

       4. Power Failure Notification
Power failures can be the cause of disasters or they may disable detection systems so that alerts are not sent out when disasters occur. For example, a power failure can disable sump pumps which can quickly cause flooding. Early notification of power failures can be extremely valuable in many applications.
The XW-112 can be configured to send out email/text notifications in the event of a power loss. This feature requires good batteries to be installed in the XW-112, and backup power must be provided to the local network that provides internet connectivity, such as a wireless access point. (Note that during times of power failure, the unit will not detect the presence of water.)

Features:

  • Wireless Wi-Fi 802.11 b/g/n
  • Built-in web server provides stand-alone operation (i.e. direct access to unit without using a cloud server - No monthly or annual service fees)
  • GRI-2605 liquid detection sensor is included
  • Powered from a 5-Volt DC power adapter
  • Two "AA" batteries provide backup power to send a power-fail alarm
  • Alarm can control relays on other ControlByWeb devices
  • Send encrypted email alarms and weekly status alerts (up to 3 addresses)
  • Simple and easy to use
  • Includes auxiliary protocols: XML and Remote Services
  • Static or DHCP IP address configuration
  • 5-year warranty

Water Leak Detection Example

       1. Equipment Monitoring
This illustration demonstrates how to monitor water leakage in a server room or any room where you have equipment you would like to protect.
The XW-112 is mounted in a dry area near the potential source of water. In this example, it is mounted above the water pipes where it will remain dry in the event of a water leak. The water sensor is mounted on the ground in an area where water would most likely accumulate.
Once mounted, the next step is to set up the XW-112 using its simple web-based setup pages. From the setup pages you will enter the information for the unit to connect to your local Wi-Fi network and send out email notifications. Sending alerts is pretty simple, but since the XW-112 is not dependent upon any cloud services or servers, you must provide all of the information required such as the email server name, your login name, email passwords, etc.
Take a look at the setup pages using our live demo unit which can be accessed here: XW-112 Demo Page.

XW-112 Part Numbers:

       XW-112-5+PS5V-2605
INPUTS: Digital: 1 (0-5VDC), Water sensor included
POWER SUPPLY: 5VDC power supply, Power supply included

Electromagnetic Compliance:

  • FCC ID: 2AE4Z-XWD001
  • IC: 21441-XWD001
  • FCC 47CFR15 (Class B)
  • IEC CISPR 22, CISPR 24
  • EN55024 ITE Immunity (2010)
  • EN55022 Emissions (2010)

Product Safety Compliance:

  • IEC 61010-1

SPECIFICATIONS

Power Requirements
Voltage5VDC power supply
Max Current 500ma max (via DC power wall adapter)
DC Jack
5.5mm barrel x 2.5mm center pin (positive)

 

Battery
InternalTwo replaceable 1.5V "AA" cells
Power Consumption59mA active RX, 229mA TX (at +12dBm)
Battery Life
On external power failure, 3 days minimum
Battery UsageBattery voltage is measured and periodically reported

 

Wireless
Network StandardsIEEE 802.11 b/g/n
Frequency Band2.412 - 2.462 GHz
Wi-Fi Security StandardsOpen, WEP, WPA, WPA2
Network SettingsDHCP or Static
Wireless RangeUp to 250ft (typical for Wi-Fi devices) depends on environment
AntennaIntegral chip antenna, 1.9 dBi.
RF Output Power (typ)14dBM (802.11b/g), 12dBM (802.11n)


Operation
ProvisioningVia internal web server (no cables or PC utilities needed)
Access PointYes, push button activated (setup via web page)
WPSYes, push button activated (Wi-Fi Protected Setup)
ConnectivityIntermittently connected or always connected
Remote Server (Optional)ControlByWeb's X-600M™, or cloud-based server
Pollingstate.xml 


Digital Inputs

Number of Relays1
Type
Non-Isolated
Current
12.4K Pullup
Minimum Hold Time
20mS
Input Functions
Monitor Liquid State, Trigger Email/Text Alerts, Control Remote Relays
Edge Trigger
Rising, Falling or Both

 

Water Sensor
ModelGRI 2605
Operating Voltage5 VDC
Operating Current10 mA
Wire ConnectionsRed: +5V
Green: In
Black: Ground
 White: Ground
Lead Wire6ft (1.83m)
Internal Push Buttons
Button 1Force access-point mode
Button 2Activate WPS mode


Physical
Size

3.16 (80mm) wide
3.04in (77mm) tall
0.91in (23mm) deep

Weight0.15 lb
Location
Indoor use or NEMA-4 protected location
Using Alkaline Batteries
-18°C to 55°C (0°F to 130°F)
Operating Temperature
-40°C to 65°C (-40°F to 150°F)
Storage Temperature
-40°C to 85°C (-40°F to 185°F)
Humidity
5-95%, non-condensing
Enclosure MaterialLexan 940 Polycarbonate Plastic
Enclosure Flame RatingUL94 V0

 

Password Settings
Password protection on setup pageYes
Password protection on control pageOptional
Password EncodingBase 64