Goodman 5 Ton Air Conditioner Condenser; 18 SEER; Two-Stage; W/R410A Refrigerant << Shipping in 48 States >>
SEER: 18; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 326;
AC condenser buying checks
Goodman 5 Ton Air Conditioner Condenser; 18 SEER; Two-Stage; W/R410A Refrigerant << Shipping in 48 States >> is part of SupplyShop's AC condenser and condenser unit selection. Use it when comparing HVAC condenser units by tonnage, SEER2 rating, refrigerant, voltage, phase, compressor staging and the matching indoor coil, furnace or air handler.
- For air conditioner condenser searches, confirm the required 2 ton, 2.5 ton, 3 ton, 4 ton or 5 ton capacity against the full system design.
- For heat pump condenser searches, verify heating application, defrost controls, refrigerant, metering device and indoor equipment compatibility before ordering.
- Match the condenser unit to the evaporator coil, air handler, furnace, thermostat controls, line-set sizing and contractor load calculation.
Related SupplyShop paths: split AC condensers, heat pump condensers, AC condenser and air handler systems, and AC evaporator coils.
$3,617.00 USD
SKU:
GSXC180601
ID:
HE101-4001
PRODUCT INFO
Standard Features
- High-efficiency two-stage scroll compressor
- High-efficiency two-speed ECM condenser fan motor
- Integrated communicating ComfortBridge™ Technology
- Commissioning and diagnostics via indoor board Bluetooth with the CoolCloud™ phone and tablet application
- Factory-installed filter drier
- Factory-installed transformer
- Factory-installed high and low-pressure switches
- High-density foam compressor sound blanket
- Copeland® ComfortAlert™ built in diagnostics
- Factory-installed sensors monitoring coil and ambient temperature
- Contactor with lug connection
- In communicating mode, only two low voltage wires to the outdoor unit are required
- AHRI Certified - ETL Listed
- Ground lug connection
- Color-coded terminal strip for non-communicating set-up
- Copper tube & enhanced aluminum fin coil
- Customized control algorithms
Cabinet Features
- Heavy-gauge galvanized steel cabinet and louvered coil guards
- Service valves with sweat connections and easy-access gauge ports
- Engineered sound control top design
- Wire fan discharge grille
- Baked-on powder-paint finish with 500-hour salt-spray approval
- Single-panel access to controls with space for field-installed accessories
- Service port and controls are accessible while unit is operating
- Compact footprint
- Rust-resistant screws
- When properly anchored, meets the 2017 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
SPECIFICATIONS
| Capacities | |
| Nominal Cooling (BTU/h) | 60,000 |
| Decibels | 74/70 |
| Compressor | |
| RLA | 22,9 |
| LRA | 147.2 |
| Horsepower | 1/3 |
| FLA | 2.80 |
| Refrigeration System | |
| Refrigerant Line Size | |
| Liquid Line Size (O.D.) | 3/8" |
| Suction Line Size (O.D.) | 1-1/8" |
| Refrigerant Connection Size | |
| Liquid Valve Size (O.D.) | 3/8" |
| Suction Valve Size (O.D.) | 7/8" |
| Valve Type | Sweat |
| Refrigerant Charge | 191 |
| Ship Weight (lbs) | 326 |