ICM ICM325A Single-Phase Head Pressure Control (120-600 VAC)
Replaces: ACT: FM2000; Hoffman: 800, 800A, 800AA, 814-50, 816-10; Ranco: E31Series; Johnson Controls: P66AAB/P66AAD; ICM: All Single Phase Head Pressure Control Models; ICM325H, ICM325HNV, ICM326HN, ICM327HN, ICM333. Including all single phase legacy LAQS Series Head Pressure Controls.
$171.79 USD
                    SKU:
                    
                  
                      ICM325A
                    
                  
                      ID:
                      
                  
                        PH501-2S9-3182
                      
                    
                    Categories:
                    
                  
                  
                  
                PRODUCT INFO
The system pressure gets too low or the condenser temperature gets too cold, the ICM325A lowers the fan speed accordingly. Other head pressure controls on the market just turn the fan off completely. This method results in inconsistent head pressure, inconsistent cooling, rattling pipes & ducts, system leaks, and ultimately a shortened life span of the condenser fan motor and compressor.
Specifications
- Operates as temperature or pressure sensitive motor fan speed control
 - Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions
 - Integral heat pump bypass circuitry allows electronic bypass of speed control
 - Eliminates overshoots common to on/off and pressure switch controls
 - Near field communication (phone tap) using the ICM OMNI App
 - Features: hard start, low temperature bypass, isolated 24 VAC supply
 - Controls up to 3 refrigeration circuits
 - RoHS compliant / lead free design
 - Typical application: A/C and heat pumps
 - Universal 120-600VAC line voltage and 24-240VAC control voltage
 - Line voltage: 120 - 600 VAC
 - Control voltage: 24-240 (Jumper enabled)
 - Frequency: 50-60 Hz
 - Operating temperature: -40°F to +176°F
 
SPECIFICATIONS
| General Information | |
| Product Type | Single Phase Control  | 
| Frequency | 50-60 Hz | 
| - Maximum | 10 amps | 
| Operating Temp Range | -40° to 176°F | 
| Sensors | 10K ohms at 77°F | 
| Application | Air Conditioners Heat Pump  | 
| Line Voltage | 120-480 VAC | 
| - Minimum | 100 mA | 
| Modulation | 70° to +100°F | 

                    
                  HVAC
                  
                    
                  
                
                    
                  Plumbing
                  
                    
                  
                
                    
                  ELECTRICAL
                  
                    
                  
                
                    
                  Tools & Test Instruments