Taco 0014-F1-1IFC Cast Iron Circulator with Integral Flow Check, 1/8 HP
Note: Full flange-to-flange three-year warranty on all 00 Series circulators.
Performance Data
Flow Range: 0-29 GPM
Head Range: 0-23 Feet
Minimum Fluid Temperature: 40+F (4+C)
Maximum Fluid Temperature: 230+F (110+C)
Maximum Working Pressure: 125 PSI
Connection Sizes: 3/4", 1", 1-1/4", 1-1/2 Flanged
The 0014-IFC with an Integral Flow Check is designed to reduce installation costs when zoning with "00" circulators on medium head/medium flow Hydronic or Radiant heating, Hydro-Air Fan Coils or closed loop solar heating systems. by locating the patented IFC inside the pump casing, a separate in-line flow check is eliminated, reducing installation costs. The reduced pressure drop of the IFC, increases the flow performance over in-line check valves. Both the IFC and cartridge are easily accessed for service instead of replacing the entire unit. The 0014-Z-IFC combines the circulator, flow-check and patented Priority Zoning control with built-in transformer, relay and priority switch in one complete, compact package to make it ideal for zoning.
Features
Typical Applications
Replacement Parts List:
Casing O-Ring: 009-028RP
Flange Gasket Set: 007-007RP
Capacitor or PC Board: 009-018RP
Cartridge Assembly Complete: 0014-004RP
Valve Assembly Trans/Relay: 0012-021RP
Performance Data
Flow Range: 0-29 GPM
Head Range: 0-23 Feet
Minimum Fluid Temperature: 40+F (4+C)
Maximum Fluid Temperature: 230+F (110+C)
Maximum Working Pressure: 125 PSI
Connection Sizes: 3/4", 1", 1-1/4", 1-1/2 Flanged
The 0014-IFC with an Integral Flow Check is designed to reduce installation costs when zoning with "00" circulators on medium head/medium flow Hydronic or Radiant heating, Hydro-Air Fan Coils or closed loop solar heating systems. by locating the patented IFC inside the pump casing, a separate in-line flow check is eliminated, reducing installation costs. The reduced pressure drop of the IFC, increases the flow performance over in-line check valves. Both the IFC and cartridge are easily accessed for service instead of replacing the entire unit. The 0014-Z-IFC combines the circulator, flow-check and patented Priority Zoning control with built-in transformer, relay and priority switch in one complete, compact package to make it ideal for zoning.
Features
- Integral Flow Check (IFC) Patent# 5,664,939
- Prevents gravity flow
- Eliminates separate in-line flow check
- Reduces installed cost, easy to service
- Improved performance vs. In-line flow checks
- Unique replaceable cartridge-Field serviceable
- Unmatched Reliability --Maintenance Free
- Quiet, efficient operation
- Direct drive-Low power consumption
- Self-lubricating, No mechanical seal
- Standard high capacity output-Compact design
- Wide range of applications
- Cast Iron or Bronze Construction, Flanged connections
Typical Applications
- Medium head/medium flow Hydronic or Radiant heating
- Hydro-Air Fan Coils
- Closed loop solar heating systems
Replacement Parts List:
Casing O-Ring: 009-028RP
Flange Gasket Set: 007-007RP
Capacitor or PC Board: 009-018RP
Cartridge Assembly Complete: 0014-004RP
Valve Assembly Trans/Relay: 0012-021RP
$776.00 USD
SKU:
0014-F1-1IFC
ID:
TC200-2S9-0450
Categories:
SPECIFICATIONS
Material | Cast Iron | |
Application | Heating | |
Max Pressure (PSI) | 125 | |
Horse Power | 1/8 | |
Flow Range (GPM) | 0-29 | |
Max Head (Ft) | 23 | |
Hertz | 60 | |
RPM | 3250 | |
Connection Type | Flanged x Flanged |
Amperage | 1.55 | |
Voltage | 115V | |
Type | Pump | |
Connection Size | 1-1/4" 1" 1-1/2" 3/4" | |
Max Flow (GPM) | 29 | |
Head Range (ft.) | 0-23 | |
Phase | 1 | |
Temperature Range (F) | 40°F to 230°F | |
Warranty | 3 Year |