Replaces: Lennox: 10M9301, 12L6901, 32M8801, 56L8401, 24L8501, 63K8901, 97L4801, 100925-01, 100925-03, 17W9201, 23W5101, 30W2501, 69M0801, 69M1501, 83M00;
White-Rodgers: 50A65-120, 50A65-121, 50A62-120, 50A62-121, 50A62-820, 21D83M-843, 50A66-122, 50A66-123

$118.15 USD

Title
Buy Now
SKU:
ICM2813
ID:
PH501-2S9-3181

PRODUCT INFO

The ICM2813 is a form, fit, and functional replacement for the Lennox SureLight(r) Series Boards and White Rodgers equivalent. The ICM2813 automated gas ignition control board monitors the ignition sequence including the inducer, pressure switch, hot surface igniter, gas valve, flame sense, and circulating blower while maintaining full safety circuit monitoring including the high limit switch, roll out switch and auxiliary limit switch circuits. Onboard diagnostics will indicate when a fault condition exists.

Product Features:

  • Controls the gas valve, inducer draft motor, circulating blower and hot surface ignitor
  • Monitors system pressure and limit switches
  • Microprocessor based precision
  • Diagnostic LEDs aid in testing and trouble shooting 

Product Specifications:

  • Electrical Rating @ 77°F (25°C)
  • Input Voltage: 18-30 VAC 50/60 Hz maximum
  • Igniter Current: 2.0 amp @ 80 VAC 50/60 Hz (resistive)
  • Inducer Relay: 2.2 FLA–3.5 LRA @ 120 VAC
  • Blower Relay: 14.5 FLA–25.0 LRA @ 120 VAC (2spd–H/C)
  • Gas Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf
  • Operating Temp Range: -40° to 176°F (-40° to 80°C)
  • Humidity Range: 5 to 95% relative humidity (non-condensing)

SPECIFICATIONS

General Information    

Product Type
Control Board
Input Voltage
18-30 VAC
Heat Blower ON Delay
45 Seconds
Cool Blower ON Delay
2 Seconds
Operating Temp Range
-40° to 176°F
Humidity Range
5% to 95% Relative Humidity (Non-Condensing)
Heat Blower OFF Delay
180 Seconds
 60 Seconds
120 Seconds
90 Seconds
Cool Blower OFF Delay
2 Seconds