ICM ICM2909 Furnace Control Boards,Rheem Replacement Boards

Availability:
In-Stock

Replaces: Rheem: 62-23599-01, 62-23599-02, 62-23599-03, 62-23599-04, 62-23599-05

$158.25 USD

Title
Buy Now
SKU:
ICM2909
ID:
PH501-2S9-3251

PRODUCT INFO

Direct Spark Ignition (DSI) Control Board

The ICM2909 DSI control replaces the following Rheem models: 62-23599(-01,-02,-03,-04,-05). The ICM2909 has incorporated LED diagnostics to assist in troubleshooting. Fault code information can be found in the application guide.

DETAILS:

  • Rheem Replacement (DSI) control board
  • Direct Spark Ignition (DSI) control board
  • Microprocessor-based
  • Monitors timing, trial for ignition, system switches, flame sensing and lockout
  • 100% lockout safety feature
  • Compatible with LP or Natural Gas
  • LED indication for status and fault codes to aid in troubleshooting

SPECIFICATIONS

General Information 

Line voltage:
208-230 VAC, 50/60 Hz
Control voltage:
18-30 VAC, 50/60 Hz 
System switches:
Vent pressure, limit and MRLC (Manual Reset Limit Control)
Heat N.C.16FLA/30 LRA @ 277 VAC, 30K @ 85°C 
Inducer:
9.8FLA/58.8LRA, 1/2HP @ 120 VAC, 6K @ 75°C 
Gas valve:2.3 A PILOT DUTY @ 240 VAC, 6K @ 75°C 
Operating temperature:-40˚F to 175˚F (-40˚C to 80˚C)
Storage temperature:
-40˚F to 185˚F (-40˚C to 85˚C)
Humidity:5% – 95% R.H. (non-condensing) at +55˚C



Pre-purge:
3 seconds

Heat blower ON delay
30 seconds

Post-purge:
5 seconds 

Heat blower OFF delay:

90 seconds

Ignition trial:
7 seconds 

Inter-purge (retrial):
15 seconds

Ignition activation period:

5 seconds 

Flame establishing period:

2 seconds

Flame failure response time:
0.8 seconds (maximum)

Cool blower On delay:

1 second 

Cool blower Off delay:

30 seconds 

Auto reset lockout:

60 minutes